Key Features
- Designed for OEM applications where the controller manufacturer implements their applications using X-10 Powerline control.
- TTL control signals
- X-10 send and receive capability
Benefits
The Two-way power line interface has been designed for controller manufacturers to implement X-10 PLC control. The functionality of the PLC control is decided by the controller manufacturer and implemented in the controller panel. The TW523/XM10 document defines the interface that the user will need for implementing X-10 control. With a control panel which has been designed to interace with X-10 PLC, the installation is simple. Just connect the XM10 to the 230V power supply and use a telephone cable to connect the unit RJ11 socket to the control panel. A red LED will glow when power is being received by the unit. It will flash slowly when X-10 signals are being exchanged.
Ducumentation and Software
Technical data
Supply Voltage: 230V +10%-15%50Hz
Ambient Temperature: -10șC to +40șC (operation)
-20șC to +70șC (storage)
Plug Type: Euro 2-pin
DC Characteristics
Serial data input:
Min.logic "1": 4V input will sink approx 2.5mA
Max.Logic "1": 20V input will sink approx 18mA
Max.logic "0": 0.8Vwill sink approx 0.1mA
(Voltages and currents with respect to terminal 2)
Note: this output is an open collector transistor. Therefore, the logic "1" voltage is quoted as a reference for defining the output leakage current. An output pullup resitor is required to generate a logic level. The pullup can be returned to any voltage up to 20V with respect of terminal 2.
AC Characteristics
HF output to ACpowerline: 60mW average into 5 ohms load (5Vpk-pk instant)
Conformity: Class 116 of EN50065-1
Carrier frequency: 120kHz ±2Khz
Width of X-10 envelope: 1ms+100 sec-50 sec
Isolation voltage: 4kV rms 50Hz for 1 min.
Approvals: CE approved
Max phase delay between 0 crossing point of AC
power line and 0 crossing detect output(either
transition) is 100”sec.
Max allowable delay between transitions on 0
crossing detect output and serial data input
"0"-"1" transition is 50”sec.
Max delay between serial input envelope "0"-"1"
transition and carrier burst reaching 90% is
50”sec.
RJ11 Connections:
1. (Black) Zero Crossing
2. (Red) Common
3. (Green) X-10 Receive
4. (Yellow) X-10 Transmit
Dimensions: Length 110, Width 65, Height 40 mm